top banner
There's No Time for Downtime | Series IEF

The Series IEF Insertion Electromagnetic Flow Transmitter is an adjustable insertion flowmeter featuring electromagnetic technology that accurately and reliably measures fluid velocity, as well as provides several continuous signal outputs. This Series is specifically designed to offer superior performance paired with simple installation and use. One unit is adjustable to fit pipe sizes from 4 to 36”, and offers several output options including selectable BACnet MS/TP or Modbus® RTU over 2-wire RS485 in addition to the standard analog, frequency and alarm outputs.

 

Applications:

  • Boiler Feed Water
  • Chilled Water
  • Open and Closed Loop Condenser Water
  • Irrigation Systems
  • Municipal Water Distribution
  • Process and Coolant Flow
  • Ground Water Remediation
  • Chemical Processing
  • Pump Protection
  • Wastewater
  • Mining


WHY BUY DWYER?  Primary Differentiators?

  • One size fits all adjustability
  • Purchased from stock with onsite setup kit
  • Available with easy to use Setup Wizard on any pipe size or pre-configured for specific application
  • Setup kit assures accuracy
    • Circumference tape measure
    • Ultrasonic pipe thickness gauge
    • Portable Programmer for non-display units
  • Display selectable BACnet/Modbus® communications
  • Excellent performance over temperature with integral temperature compensating RTDs
  • High reliability and ruggedness


Features and Benefits:

  • Field configurable, integral, or remote setup displays allow for ultimate flexibility by accommodating a variety of application configurations with one model through multiple display configurations 
    • i.e.- pipe size, pipe material, liquid type, liquid temperature, analog output, pulse/frequency output, alarm outputs, communication outputs, damping, and calibration factor
  • High performance accuracy is unaffected by change in temperature, density or viscosity
  • Setup Wizard and installation tool are simple to use allowing for quick and precise installation
  • Accessory setup kit ensures exact installation application depth
  • Long life cycle and minimal maintenance requirements with no moving parts to wear or break and electrodes that discourage fouling
  • Isolation valve accessory options allow for installation in operational systems via a hot-tap kit for easy removal without system downtime
  • NIST calibration certificate included standard
  • NSF/ANSI 61 and 372 approval for drinking water system components




Change Lead Form